Nami Sanat Co.

Menu ccc


KFD2-PT.EX1-5, , 24 V DC supply (Power Rail) • Potentiometer input,KFD2-PT.EX1-5,KFD2-PT.EX1-,KFD2-PT.EX1,KFD2-PT.EX,KFD2-PT.E,KFD2-PT.,KFD2-PT,KFD2-P,KFD2-,KFD2,KFD,KF,k,K, ,Current output 4 mA ... 20 mA ,Lead resistance compensation adjustment ,Accuracy 0.05 % ,Up to SIL 2 acc. to IEC 61508, 1 N/C contact, ,نامی صنعت,تجهیزات صنعتی برق صنعتی,namisanat,نامی صنعت,تجهیزات صنعتی,نمایندگی فروش سایر برند ها,نمایندگی فوش ایر برند های ABB,IFM,ind.power,برق صنعتی ,ind,power,برق ,صنعتی ,This isolated barrier is used for intrinsic safety applications. It provides the source voltage to a potentiometer and transfers its wiper position from hazardous areas to safe areas. It then converts the signal to a 4 mA ... 20mA current output. The unit can be used in a 3-, 4-, or 5-wire configuration depending on the required measurement accuracy. Terminals 2 and 5 are used as the sense line for the potentiometer lead resistance compensation in a 5-wire configuration. The barrier’s potentiometer can be used to compensate for lead resistance up to 5 % of the hazardous area potentiometer value,Signal type Analog input Functional safety related parameters Safety Integrity Level (SIL) SIL 2 Supply Connection Power Rail or terminals 11+, 12- Rated voltage Ur 20 ... 35 V DC Ripple within the supply tolerance Power dissipation 1 W Power consumption 1.3 W Input Connection side field side Connection terminals 4-, 5-, 3+, 2+, 1+ Potentiometer Types of measuring 3-, 4-, 5-wire technology Nominal resistance 800 Ω to 100 kΩ Supply voltage approx. 4.7 V Lead resistance 5 % of the potentiometer resistance (adjustable) Output Connection side control side Connection terminals 7-, 8+ Current output 4 ... 20 mA, load ≤1 kΩ Transfer characteristics Accuracy 0.05 % Deviation Linearity ± 10 µA Influence of ambient temperature ≤ 1 µA/K Rise time 10 to 90 % ≤ 8 ms; 10 to 90 % within 1 % of span ≤ 25 ms Galvanic isolation Output/power supply functional insulation, rated insulation voltage 50 V AC Indicators/settings Control elements potentiometer Configuration via potentiometer Directive conformity Electromagnetic compatibility, Directive 2014/30/EU EN 61326-1:2013 (industrial locations) Conformity, Electromagnetic compatibility NE 21:2006, Degree of protection IEC 60529:2001, Protection against electrical shock UL 61010-1, Ambient conditions, Ambient temperature -20 ... 60 °C (-4 ... 140,, °F) Mechanical specifications Degree of protection IP20, Connection screw terminals, Mass approx. 120 g, Dimensions 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001,

KFD2-PT.EX1-5

Pepperl+Fuchs / Pepperl+Fuchs

Group: Ind. Power

Subgroup: Relay

SubSubgroup: Other Relays

Brand: Pepperl+Fuchs

Detail:

KFD2-PT.EX1-5

RELAY

DATASHEET

Similar Products

You can sign up to our news letter for more information about our products: Sign up Now !